Services/Testing · Air Barrier and Ducts
Blower Door, Air Tightness and Duct Leakage Testing
A blower door test puts a number on how airtight a building is, and a duct leakage test does the same for the ductwork. We measure the leakage with Retrotec equipment and, with infrared, show exactly where the air barrier or the ducts are leaking, so the fix goes in the right place.
- ASTM E779
- ASTM E3158
- ASTM E1554
- ASTM E1186
- Energy code

Where This Helps Most
Energy Code or the Spec Requires It
Whole building air tightness testing for code compliance, project specifications and certification programs.
Before the Air Barrier Is Covered
Test early, while leaks can still be sealed easily.
Ductwork Needs Verifying
Duct leakage testing on new or renovated systems, before ceilings and chases close up.
Comfort, Moisture or Odor Problems
Drafts, condensation and odors that point to air or duct leaks.
From First Call to Final Report
Prepare
We agree on the test standard and target, and the conditions the building or system needs to be in.
Test
Whole building testing with Retrotec blower door equipment to ASTM E779, or ASTM E3158 with multiple fans for large and multizone buildings. Duct leakage testing to ASTM E1554.
Find the Leaks
Infrared during the test, following ASTM E1186, to locate leak paths at shafts, parapets, rim joists, penetrations and duct connections.
Report
Measured leakage against the target, with photos of the leak locations and what to seal before a retest.
Clear Findings You Can Act On
- A test report with the measured air or duct leakage and pass / fail against the target
- Leak locations with infrared and regular photos
- Recommendations for sealing before a retest
- Every report and photo in your project's client portal


Common Questions
When should the test happen?
Ideally twice: once while the air barrier is still exposed, so leaks are easy to fix, and once at completion for the final number.
What does the building need to be like?
Exterior doors and windows installed and closed, HVAC and exhaust openings sealed or controlled, and access to the whole building. We'll send a prep checklist.
Can you test large buildings?
Yes, with multiple fans following ASTM E3158 for large or multizone buildings.
Is infrared included?
It's an option we recommend. It turns a single number into a map of where to seal.
Do you test duct leakage?
Yes, with Retrotec duct testing equipment following ASTM E1554, for total leakage or leakage to outside. If a code official or program requires a specific certified tester to sign off, tell us the program up front and we'll confirm what's needed before we schedule.
Do you test multifamily buildings?
Yes. We test whole buildings, and individual units or corridors where the project calls for compartment testing, and combine the results with infrared so the contractor knows what to seal.
Infrared Thermography
Drone and handheld infrared roof moisture scans and wall thermography by an ITC Level III thermographer.New constructionConstruction QA Site Visits
Building envelope QA site visits for multifamily and commercial new construction: WRB, flashing, windows and roofing, with reports in about 48 hours.New constructionBuilding Envelope Design Review
Third-party review of architectural drawings for waterproofing and envelope detailing.Field-tested answers. Defensible reports.
Tell us about the building and we'll reply within one business day with next steps and a proposal.